sane-u12 - SANE backend for Plustek USB flatbed scanners,
based on older parport designs
DESCRIPTION
The
sane-u12
library implements a SANE (Scanner Access Now Easy) backend that
provides access to USB flatbed scanners based on Plusteks' ASIC
98003 (parallel-port ASIC) and a GeneSys Logics' USB-parport
bridge chip.
SUPPORTED DEVICES
The backend is able to support some early Plustek USB scanner based
their old parport design around the ASIC 98003 and other rebadged
Plustek devices. The following tables will give you a short overview.
If your Plustek scanner has another Product ID, then the device is
NOT
supported by this backend.
--------------------------------------------------------
USB Model: Vendor-ID: Product-ID:
--------------------------------------------------------
ColorPage Vivid III USB 0x07B3 0x0001
ColorPage HR6 V1 0x0458 0x2004
CONFIGURATION
To use your scanner with this backend, you need at least two
entries in the configuration file
/etc/sane.d/u12.conf
[usb] vendor-id product-id device /dev/usbscanner
[usb]
tells the backend, that the following devicename (here
/dev/usbscanner)
has to be interpreted as USB scanner device. If vendor- and
product-id has not been specified, the backend tries to
detect this by its own. If device is set to
auto
then the next matching device is used.
The Options:
option warmup t
t
specifies the warmup period in seconds
option lampOff t
t
is the time in seconds for switching off the lamps in
standby mode
option lOffonEnd b
b
specifies the behaviour when closing the backend, 1 --> switch
lamps off, 0 --> do not change lamp status
See the u12.conf file for examples.
Note:
You have to make sure, that the USB subsystem is loaded
correctly and you have access to the device-node. For
more details see
sane-usb (5)
manpage. You might use
sane-find-scanner
to check that you have access to your device.
Note:
If there's no configuration file, the backend defaults to
device auto
FILES
/etc/sane.d/u12.conf
The backend configuration file
/usr/lib/sane/libsane-u12.a
The static library implementing this backend.
/usr/lib/sane/libsane-u12.so
The shared library implementing this backend (present on systems that
support dynamic loading).
ENVIRONMENT
SANE_CONFIG_DIR
This environment variable specifies the list of directories that may
contain the configuration file. Under UNIX, the directories are
separated by a colon (`:'), under OS/2, they are separated by a
semi-colon (`;'). If this variable is not set, the configuration file
is searched in two default directories: first, the current working
directory (".") and then in /etc/sane.d. If the value of the
environment variable ends with the directory separator character, then
the default directories are searched after the explicitly specified
directories. For example, setting
SANE_CONFIG_DIR
to "/tmp/config:" would result in directories "tmp/config", ".", and
"/etc/sane.d" being searched (in this order).
SANE_DEBUG_U12
If the library was compiled with debug support enabled, this
environment variable controls the debug level for this backend. Higher
debug levels increase the verbosity of the output.
To obtain debug messages from the backend, please set the
environment-variable
SANE_DEBUG_U12
before calling your favorite scan-frontend (i.e. xscanimage).
i.e.: export SANE_DEBUG_U12=20 ; xscanimage
The value controls the verbosity of the backend.
KNOWN BUGS & RESTRICTIONS
* The driver is in alpha state, so please don't expect too much!!!
* When using libusb, it might be, that the backend hangs.
In that case, reconnect the scanner.