    NAME

    cfgadm_pci - PCI, CompactPCI, and PCI Express Hotplug hardware specific commands for cfgadm
     
    

    SYNOPSIS

    /usr/sbin/cfgadm [-f] [-y | -n] [-v] 
        [-o hardware_options] -c function ap_id [ap_id]
    

    /usr/sbin/cfgadm [-f] [-y | -n] [-v] 
        [-o hardware_options] -x hardware_function ap_id 
        [ap_id]
    

    /usr/sbin/cfgadm [-v] [-s listing_options] 
        [-o hardware_options] [-l [ap_id | ap_type]]
    

    /usr/sbin/cfgadm [-v] [-o harware_options] -t ap_id [ap_id]
    

    /usr/sbin/cfgadm [-v] [-o hardware_function] -h 
        [ap_id| ap_type]
    

     

    DESCRIPTION

    The PCI hardware specific library, /usr/lib/cfgadm/pci.so.1, provides the support for hot plugging PCI, CompactPCI, and PCI Express adapter cards into the respective hot pluggable slots in a system that is hot plug capable, through the cfgadm command (see cfgadm(1M)). Hot plug administrative models between PCI, CompactPCI, and PCI Express remain the same except where noted in this document.

    For PCI Hot Plug, each hot plug slot on a specific PCI bus is represented by an attachment point of that specific PCI bus.

    An attachment point consist of two parts: a receptacle and an occupant. The receptacle under PCI hot plug is usually referred to as the physical hot pluggable slot; and the occupant is usually referred to as the PCI adapter card that plugs into the slot.

    Attachment points are named through ap_ids. There are two types of ap_ids: logical and physical. The physical ap_id is based on the physical pathname, that is, /devices/pci@1/hpc0_slot3, whereas the logical ap_id is a shorter, and more user-friendly name. For PCI hot pluggable slots, the logical ap_id is usually the corresponding hot plug controller driver name plus the logical slot number, that is, pci0:hpc0slot1; PCI nexus driver, with hot plug controller driver named hpc and slot number 1. The ap_type for Hot plug PCI is pci.

    Note that the ap_type is not the same as the information in the Type field.

    See the for a detailed description of the hot plug procedure.  

    PCI Express ap_id naming

    For attachment points located in a PCI Express hierarchy (that is, the parent or an ancestor is a PCI Express device), including attachment points which are not PCI Express devices themselves, the following naming scheme is used:

    Grammar:
      APID : absolute-slot-path
    
      absolute-slot-path : slot-path[:slot-path[:slotpath ...]]
    
      slot-path : [fru-id.]slot-id
              where fru-id indicates the chassis FRU, if any, 
              containing the slot-id
    
      fru-id : fru-type[serialid#]
              where fru-type is "iob" for PCI Express expansion 
              chassis, followed by its serial number serialid#,
              if available
    
       slot-id: slot-name | device-type physical-slot# |\
               nexus-driver-name nexus-driver-instance.\
               device-type pci-device-number         
    

    where slot-name is a name assigned by the platform or hardware itself; device-type is either "pcie"for PCI Express devices or "pci" for PCI devices; nexus-driver-name is the driver name for the device component; physical-slot# is the hardware slot number; and pci-device-number is the PCI device number in standard PCI nomenclature.

    First, an absolute-slot-path is constructed that attempts to describe the attachment point's topological location in more physically identifiable terms for the user . This absolute-slot-path consists of slot-path components each seperated by a ":" (colon). The leaf or left-most slot-path component describes the device of the attachment point itself while its right adjacent slot-path component up to the right or top-most slot-path component describes the parent up to the root devices, respectively.

    Each slot-path consists of a slot-id optionally preceded by an fru-id, which indicates an expansion chassis containing the device described by slot-id (detailed below). fru-id consists of fru-type followed by an optional serialid#. fru-type is "iob" for PCI Express expansion chassis types, while serialid# is either a 64-bit hexadecimal number indicating a raw serial number obtained from the expansion chassis hardware, or a 4 upper-case ASCII character sequence for Sun branded expansion chassis.

    Each slot-id consists of one of three possible forms:

    slot-id form (1)

    slot-names

    slot-id form (2)

    device-type physical-slot#

    slot-id form (3)

    nexus-driver-name nexus-driver-instance. device-type pci-device-number

    The precedence of which form to select flows from the lowest form number to the highest form number, or from top to bottowm as described above. If a form cannot be successfully constructed, then the next numerically higher form is attempted.

    The slot-names in "slot-id form (1)" is taken from the "slot-names" property of the corresponding node in the device tree and is a name assigned by hardware or the platform. This format is not predefined or established.

    In "slot-id form (2)", device-type indicates the device type of the component's slot, and is either "pcie" for PCI Express or "pci" for PCI, while physical-slot#, take from the "physical-slot#" property of its corresponding device node, indicates the hardware slot number of the component.

    "slot-id form (3)" is used when all other forms cannot successfully be constructed, and is considered to be the default form. nexus-driver-name is the component's driver name; nexus-driver-instance is such driver's instance; device-type is the same as described in form (2); pci-device-type is the PCI device number as described and used for device configuration cycles in standard PCI nomenclature.

    In summary of the slot-path component, expanding the optional FRU component that may precede it, slot-path will consist one of the following forms in order:

    (1) [ iob[serialid#]. ] slot-names
    (2) [ iob[serialid#]. ] device_type physical_slot#
    (2) [ iob[serialid#]. ]
             nexus-driver-name nexus-driver-instance.
             device_type pci-device-number
    

    Lastly, the final form of the actual ap_id name used in cfgadm is decided as follows, specified in order of precedence:

    ap_id form (1)

    if the absolute-slot-path can fit within the fixed length limit of cfgadm's ap_id field, then absolute-slot-path itself is used

    ap_id form (2)

    (absolute-slot-path exceeds the ap_id length limit) if the last slot_path component is contained within an expansion chassis, and it contains a serialid#, then the last slot_path component is used. The requirement for a serialid# in this form is to ensure a globally unique ap_id.

    ap_id form (3)

    (absolute-slot-path exceeds the ap_id length limit) the default form, "slot-id form (3)", of the last slot_path component is used

    Whichever final ap_id name is used, the absolute-slot-path is stored in the Information ("info") field which can be displayed using the -s or -voptions. This information can be used to physically locate any ap_ids named using "ap_id form (2)" or "ap_id form (3)". The absolute-slot-path is tranformed slightly when stored in the information field, by the replacement of a colon (":") with forward slashes ("/") to more closely denote a topological context. The absolute-slot-path can include slot-path components that are not hotpluggable above the leaf or right-most slot-path component up to the onboard host slot.

    See the EXAMPLES section for a list of hotpluggable examples.  

    OPTIONS

    The following options are supported:

    -c function

    The following functions are supported for PCI hot pluggable slots:

    configure

    Configure the PCI device in the slot to be used by Solaris.

    connect

    Connect the slot to PCI bus.

    disconnect

    Disconnect the slot from the PCI bus.

    insert

    Not supported.

    remove

    Not supported.

    unconfigure

    Logically remove the PCI device's resources from the system.

    -f

    Not supported.

    -h ap_id | ap_type

    Print out PCI hot plug specific help message.

    -l list

    List the values of PCI Hot Plug slots.

    -o hardware_options

    No hardware specific options are currently defined.

    -s listing_options

    Same as the generic cfgadm(1M).

    -t ap_id

    This command is only supported on platforms which support testing capability on the slot.

    -v

    Execute in verbose mode.

    When the -v option is used with the -l option, the cfgadm command outputs information about the attachment point. For attachment points located in a PCI Express hierarhcy, the Information field will contain the attachment point's absolute slot path location, including any hardware or platform specific labeling information for each component in the slot path. Each component in the slot path will be seperated by a "/" (foward slash). See the PCI Express ap_id naming section. For PCI Hot Plug attachment points not located in a PCI Express hieararchy, the Information field will be the slot's system label, if any. This string will be obtained from the slot-name property of the slot's bus node. The information in the Type field is printed with or without the -v option. The occupant Type field will describe the contents of the slot. There are 2 possible values:

    unknown

    The slot is empty. If a card is in the slot, the card is not configured or there is no driver for the device on the card.

    subclass/board

    The card in the slot is either a single-function or multi-function device.

    subclass is a string representing the subclass code of the device, for example, SCSI, ethernet, pci-isa, and so forth. If the card is a multi-functional device, MULT will get printed instead.

    board is a string representing the board type of the device. For example, hp is the string used for a PCI Hot Plug adapter, hs is used for a Hot Swap Board, nhs for a Non---Hot Swap cPCI Board, bhs for a Basic Hot Swap cPCI Board, and fhs for a Full Hot Swap cPCI Board.

    Most PCI cards with more than one device are not multi-function devices, but are implemented as a PCI bridge with arbitrary devices behind them. In those cases, the subclass displayed is that of the PCI bridge. Most commonly, the bridges are pci-pci, a generic PCI to PCI bridge or stpci, a semi-transparent PCI bridge.

    -x hardware_function

    Perform hardware specific function. These hardware specific functions should not normally change the state of a receptacle or occupant.

    The following hardware_functions are supported:

    enable_slot | disable_slot

    Change the state of the slot and preserve the state of slot across reboot. Preservation of state across reboot is only supported on select platforms.

    enable_slot enables the addition of hardware to this slot for hot plugging and at boot time.

    disable_slot disables the addition of hardware to this slot for hot plugging and at boot time. When a slot is disabled its condition is shown as unusable.

    enable_autoconfig | disable_autoconfig

    Change the ability to autoconfigure the occupant of the slot. Only platforms that support auto configuration support this feature.

    enable_autoconfig enables the ability to autoconfigure the slot.

    diable_autoconfig disables the ability to autoconfigure the slot.

    Autoconfiguration is done through the attention button on the PCI Express platforms and through the injector/ejector latch on the CompactPCI platforms. When autoconfiguration is disabled, the attention button or latch mechanism cannot be used to configure the occupant of the slot.

    led=[led_sub_arg],mode=[mode_sub_arg]

    Without sub-arguments, print a list of the current LED settings. With sub-arguments, set the mode of a specific LED for a slot.

    Specify led_sub_arg as fault, power, attn, or active.

    Specify mode_sub_arg as on, off or blink.

    For PCI Express, only the power and attn LEDs are valid and only the state of the attn LED can be changed.

    Changing the state of the LED does not change the state of the receptacle or occupant. Normally, the LEDs are controlled by the hot plug controller, no user intervention is necessary. Use this command for testing purposes.

    Caution: Changing the state of the LED can misrepresent         the state of occupant or receptacle.

    The following command prints the values of LEDs:

    example#  cfgadm -x led pci0:hpc0_slot1
    Ap_Id             Led
    pci0:hpc0_slot1   power=on,fault=off,active=off,attn=off
    

    The following command turns on the Fault LED:

    example# cfgadm -x led=fault,mode=on pci0:hpc0_slot1
    

    The following command turns off the Power LED:

    example# cfgadm -x led=power,mode=off pci0:hpc0_slot0
    

    The following command sets the active LED to blink to indicate the location of the slot:        

    example# cfgadm -x led=active,mode=on pci0:hpc0_slot3
    

     

    EXAMPLES

    Example 1 Printing out the Value of Each Slot

    The following command prints out the values of each slot:

    example# cfgadm -l
    Ap_Id            Type         Receptacle   Occupant       Condition
    c0               scsi-bus     connected    configured     unknown
    c1               scsi-bus     connected    unconfigured   unknown
    c2               scsi-bus     connected    unconfigured   unknown
    cpci_slot1       stpci/fhs    connected    configured     ok
    cpci_slot2       unknown      empty        unconfigured   unknown
    cpci_slot4       stpci/fhs    connected    configured     ok
    cpci_slot5       stpci/fhs    connected    configured     ok
    pcie7            etherne/hp   connected    configured     ok
    pcie8            unknown      empty        unconfigured   unknown
    pcie9            fibre/hp     connected    configured     ok
    

    Example 2 Replacing a Card

    The following command lists all DR-capable attachment points:

    example# cfgadm
    
    
    Type             Receptacle   Occupant     Condition
    c0               scsi-bus     connected    configured     unknown
    c1               scsi-bus     connected    unconfigured   unknown
    c2               scsi-bus     connected    unconfigured   unknown
    cpci_slot1       stpci/fhs    connected    configured     ok
    cpci_slot2       unknown      empty        unconfigured   unknown
    cpci_slot4       stpci/fhs    connected    configured     ok
    cpci_slot5       stpci/fhs    connected    configured     ok
    pcie7            etherne/hp   connected    configured     ok
    pcie8            unknown      empty        unconfigured   unknown
    pcie9            fibre/hp     connected    configured     ok
    

    The following command unconfigures and electrically disconnects the card:

    example# cfgadm -c disconnect cpci_slot4
    

    The change can be verified by entering the following command:

    example# cfgadm cpci_slot4 
    
    
    Ap_Id                   Type         Receptacle   Occupant     Condition
    cpci_slot4              unknown      disconnected unconfigured unknown
    

    Now the card can be swapped. The following command electrically connects and configures the card:

    example# cfgadm -c configure cpci_slot4
    

    The change can be verifed by entering the following command:

    example# cfgadm cpci_slot4 
    
    
    Ap_Id                   Type         Receptacle   Occupant     Condition
    cpci_slot4              stpcipci/fhs connected    configured   ok
    

    Example 3 Interpreting ApIds for devices in a PCI Express topology

    The following command shows a listing for a topology with both PCI Express and PCI attachment points in I/O expansion chassis connected to hotpluggable slots at the host level:

    example# cfgadm -s cols=ap_id:info
    
    
    Ap_Id                          Information
    iou#0-pci#0                    Location: iou#0-pci#0
    iou#0-pci#1                    Location: iou#0-pci#1
    iou#0-pci#1:iob.pci3           Location: iou#0-pci#1/iob.pci3
    iou#0-pci#1:iob.pci4           Location: iou#0-pci#1/iob.pci4
    iou#0-pci#2                    Location: iou#0-pci#2
    iou#0-pci#2:iob58071.pcie1     Location: iou#0-pci#2/iob58071.pcie1
    iou#0-pci#2:iob58071.special   Location: iou#0-pci#2/iob58071.special
    iou#0-pci#3                    Location: iou#0-pci#3
    iou#0-pci#3:iobBADF.pcie1      Location: iou#0-pci#3/iobBADF.pcie1
    iou#0-pci#3:iobBADF.pcie2      Location: iou#0-pci#3/iobBADF.pcie2
    iou#0-pci#3:iobBADF.pcie3      Location: iou#0-pci#3/iobBADF.pcie3
    iou#0-pci#3:iobBADF.pci1       Location: iou#0-pci#3/iobBADF.pci1
    iou#0-pci#3:iobBADF.pci2       Location: iou#0-pci#3/iobBADF.pci2
    

    In this example, the "iou#0-pci#[0-3]" represents the top-most hotpluggable slots in the system. Since the "iou#<n>-pci#<n>" form does not match any of the forms stated in the grammar specification section described earilier, we can infer that such a name for the base component in this hotplug topology is derived from the platform through the "slot-names" property.

    Slot iou#0-pci#0

    this slot is empty or its occupant is unconfigured

    Slot iou#0-pci#1

    this slot contains an expansion chassis with two hotpluggable slots, "pci3" and "pci4". "pci3" and "pci4" represent two PCI slots contained within that expansion chassis with physical slot numbers 3 and 4 respectively. The expansion chassis in this case does not have or exports a serial-id.

    Slot iou#0-pci#2

    this slot contains a third party expansion chassis with a hexadecimal serial-id of 58071. Within that expansion chassis are two hotpluggable slots, "pcie1" and "special". "pcie1" represents a PCI Express slot with physical slot number 1. The slot "special" has a label which is derived from the platform, hardware or firmware.

    Slot iou#0-pci#3

    this slot contains a Sun expansion chassis with an FRU identifier of "BADF". This expansion chassis contains three PCI Express slots, "pcie1", "pcie2", and "pcie3" with physical slot numbers 1, 2, and 3 respectively; and two PCI slots, "pci1" and "pci2" with physical slot numbers 1 and 2, respectively.

    The following command shows a listing for a topology with both PCI Express and PCI attachment points in I/O expansion chassis connected hotpluggable and non-hotpluggable host slots:

    example# cfgadm -s cols=ap_id:info
    
    
    Ap_Id                          Information
    Slot1                          Location: Slot1
    Slot2:iob4ffa56.pcie1          Location: Slot2/iob4ffa56.pcie1
    Slot2:iob4ffa56.pcie2          Location: Slot2/iob4ffa56.pcie2
    Slot5:iob3901.pci1             Location: Slot2/iob3901.pci1
    Slot5:iob3901.pci2             Location: Slot2/iob3901.pci2
    

    In this example, the host system only has one hotpluggable slot, "Slot1". We can infer that "Slot2" and "Slot5" are not hotpluggable slots because they do not appear as attachment points themselves in cfgadm. However, "Slot2" and "Slot5" each contains a third party expansion chassis with hotpluggable slots.

    The following command shows a listing for a topology with attachment points that are lacking in certain device properties:

    example# cfgadm -s cols=ap_id:info
     
    Ap_Id                          Information
    px_pci7.pcie0                  Location: px_pci7.pcie0
    px_pci11.pcie0                 Location: px_pci11.pcie0
    px_pci11.pcie0:iob.pcie1       Location: px_pci11.pcie0/iob.pcie1
    px_pci11.pcie0:iob.pcie2       Location: px_pci11.pcie0/iob.pcie2
    px_pci11.pcie0:iob.pcie3       Location: px_pci11.pcie0/iob.pcie3
    

    In this example, the host system contains two hotpluggable slots, "px_pci7.pcie0" and "px_pci11.pcie0". In this case, it uses "slot-id form (3)" ( the default form) for the base slot-path component in the absolute-slot-path because the framework could not obtain enough information to produce other more descriptive forms of higher precedence.

    Interpreting right-to-left, attachment point "px_pci7.pcie0" represents a PCI Express slot with PCI device number 0 (which does not imply a physical slot number of the same), bound to nexus driver "px_pci", instance 7. Likewise, attachment point "px_pci11.pcie0" represents a PCI Express slot with PCI device number 0 bound to driver instance 11 of px_pci.

    Under "px_pci11.pcie0" is a third party expansion chassis without a serial-id and with three hotpluggable PCI Express slots.

    The following command shows a listing for a topology with attachment point paths exceeding the ApId field length limit:

    example# cfgadm -s cols=ap_id:info
    
    Ap_Id                          Information
    pcie4                          Location: pcie4
    pcie4:iobSUNW.pcie1            Location: pcie4/iobSUNW.pcie1
    pcie4:iobSUNW.pcie2            Location: pcie4/iobSUNW.pcie2
    iob8879c3f3.pci1               
                      Location: pcie4/iobSUNW.pcie2/iob8879c3f3.pci1
    iob8879c3f3.pci2               
                      Location: pcie4/iobSUNW.pcie2/iob8879c3f3.pci2
    iob8879c3f3.pci3               
                      Location: pcie4/iobSUNW.pcie2/iob8879c3f3.pci3
    

    In this example, there is only one hotpluggable slot, "pcie4" in the host. Connected under "pcie4" is a SUN expansion chassis with FRU identifier "SUNW". Nested under PCI Express slot "pcie2" of that expansion chassis (ApId pcie4:iobSUNW.pcie2) lies another expansion chassis with three hotpluggable PCI slots.

    Because the length of the absolute-slot-path form of "pcie4/iobSUNW.pcie2/iob8879c3f3.pci1...3" exceeds the ApId field length limit, and the leaf slot-path component is globally unique, "ap_id form (2)" is used, where the leaf slot-path component in the absolute-slot-path is used as the final ApId.

    The following command shows a listing for a topology with attachment point paths exceeding the ApId field length limit and lacking enough information to uniquely identify the leaf slot-id on its own (for instance, missing the serial-id):

    example# cfgadm -s cols=ap_id:info
    
    
    Ap_Id                          Information
    pcie4                          Location: pcie4
    pcie4:iob4567812345678.pcie3   Location: pcie4/iob4567812345678.pcie3
    px_pci20.pcie0                 
                      Location: pcie4/iob4567812345678.pcie3/iob.pcie1
    px_pci21.pcie0                       
                      Location: pcie4/iob4567812345678.pcie3/iob.pcie2
    

    In this example, there is only one hotpluggable slot, "pcie4" in the host. Connected under "pcie4" is a third party expansion chassis with hexadecimal serial-id 4567812345678. Nested under the PCI Express slot "pcie3" of that expansion chassis (ApId pcie4:iob4567812345678.pcie3), lies another third part expansion chassis without a serial-id and with two hotpluggable PCI Express slots.

    Because the length of the absolute-slot-path form of "pcie4/iob4567812345678.pcie3/iob.pcie1...2" exceeds the ApId field length limit, and the leaf slot-path component is not globally unique, "ap_id form (3)" is used. "ap_id form (2)" is where slot-id form (3) (default form) of the leaf slot-path component in the absolute-slot-path is used as the final ApId.

    The default form or "slot-id form (3)" of the leaf component ".../iob.pcie1"represents a PCI Express slot with device number 0, bound to driver instance 20 of "px_pci". Likewise, the default form of the leaf component ".../iob.pcie2" represents a PCI Express slot with device number 0, bound to driver instance 21 of "px_pci"

     

    FILES

    /usr/lib/cfgadm/pci.so.1

    Hardware specific library for PCI hot plugging.

     

    ATTRIBUTES

    See attributes(5) for descriptions of the following attributes:

    ATTRIBUTE TYPEATTRIBUTE VALUE

    AvailabilitySUNWcsl

     

    SEE ALSO

    cfgadm(1M), config_admin(3CFGADM), libcfgadm(3LIB), attributes(5)


     

    Index

    NAME
    SYNOPSIS
    DESCRIPTION
    PCI Express ap_id naming
    OPTIONS
    EXAMPLES
    FILES
    ATTRIBUTES
    SEE ALSO


    Поиск по тексту MAN-ов: 




    Партнёры:
    PostgresPro
    Inferno Solutions
    Hosting by Hoster.ru
    Хостинг:

    Закладки на сайте
    Проследить за страницей
    Created 1996-2024 by Maxim Chirkov
    Добавить, Поддержать, Вебмастеру