fcinfo, fcadm - Fibre Channel HBA Port Command Line Interface
fcinfo hba-port [-lit] [HBA_port_WWN]...
fcadm hba-port [-lit] [HBA_port_WWN]...
fcinfo remote-port [-ls] [-p HBA_port_WWN] [REMOTE_port_WWN]...
fcadm remote-port [-ls] [-p HBA_port_WWN] [REMOTE_port_WWN]...
fcinfo logical-unit | lu [-v] [OS device_path]
fcadm logical-unit | lu [-v] [OS device_path]
fcadm create-npiv-port -p Virtal_Port_WWN [-n Virtual_Node_WWN] PhysicalPort_port_WWN
fcadm delete-npiv-port -p Virtal_Port_WWN [-n Virtual_Node_WWN] PhysicalPort_port_WWN
fcinfo [-V]
fcadm [-V]
fcinfo [-?]
fcadm [-?]
fcinfo and fcadm are command line interfaces that collect administrative information on fibre channel host bus adapter (HBA) ports on a host. They also collect data on any fibre channel targets that might be connected to those ports in a Storage Area Network (SAN).
A port can be either in initiator mode or target mode. The same FC attribute information and remote port information are applied to both the initiator and the target modes port except that SCSI-related operations described below do not apply for the target mode port.
The following subcommands are supported by both fcinfo and fcadm:
hba-port
remote-port
logical-unit | lu
The following subcommands, which administer N_Port ID Virtualization (NPIV) HBA ports, are supported only by fcadm:
create-npiv-port
delete-npiv-port
The following options are supported:
-l, --linkstat
-i [HBA_node_WWN], -initiator [HBA_node_WWN]
-n HBA_node_WWN, --node HBA_node_WWN
-p HBA_port_WWN, --port HBA_port_WWN
When used with NPIV options, specify a virtual port WWN. If used with create-npiv-port, it can be omitted, and a random based WWN will be used. It is mandatory for delete-npiv-port.
-s, --scsi-target
-t [HBA_node_WWN], -target [HBA_node_WWN]
-v, --verbose
-V, --version
-?, --help
Example 1 Listing All HBA Ports
The following command lists all initiator mode fibre channel HBA ports on the host:
# fcinfo hba-port HBA Port WWN: 210000e08b074cb5 Port Mode: Initiator OS Device Name: /dev/cfg/c1 Manufacturer: QLogic Corp. Model: 375-3108-xx Firmware Version: 3.3.116 FCode/BIOS Version: 1.13.08 Serial Number: not available Driver Name: qlc Driver Version: 20070212-2.19 Type: N-port State: online Supported Speeds: 1Gb 2Gb Current Speed: 2Gb Node WWN: 200000e08b074cb5 NPIV Port List: Virtual Port 1: Port WWN: 200000e08b074cb1 Node WWN: 200000e08b074cb3 HBA Port WWN: 210100e08b274cb5 Port Mode: Initiator OS Device Name: /dev/cfg/c2 Manufacturer: QLogic Corp. Model: 375-3108-xx Firmware Version: 3.3.116 FCode/BIOS Version: 1.13.08 Serial Number: not available Driver Name: qlc Driver Version: 20070212-2.19 Type: N-port State: online Supported Speeds: 1Gb 2Gb Current Speed: 2Gb Node WWN: 200100e08b274cb5 HBA Port WWN: 210000e08b072ab5 Port Mode: Initiator OS Device Name: /dev/cfg/c3 Manufacturer: QLogic Corp. Firmware Version: 3.3.116 FCode/BIOS Version: 1.13.08 Model: 375-3108-xx Serial Number: not available Driver Name: qlc Driver Version: 20070212-2.19 Type: L-port State: online Supported Speeds: 1Gb 2Gb Current Speed: 2Gb Node WWN: 200000e08b072ab5 HBA Port WWN: 210100e08b272ab5 Port Mode: Initiator OS Device Name: /dev/cfg/c4 Manufacturer: QLogic Corp. Model: 375-3108-xx Firmware Version: 3.3.116 FCode/BIOS Version: 1.13.08 Serial Number: 0402F00-0549112808 Driver Name: qlc Driver Version: 20070212-2.19 Type: N-port State: online Supported Speeds: 1Gb 2Gb Current Speed: 2Gb Node WWN: 200100e08b272ab5
Example 2 Listing Target Mode HBA Ports
The following command lists all target mode fibre channel HBA ports on the host:
# fcinfo hba-port -t HBA Port WWN: 210100e08bb09221 Port Mode: Target Port ID: 10700 OS Device Name: Not Applicable Manufacturer: QLogic Corp. Model: d30ac7e0 Firmware Version: 4.0.109 FCode/BIOS Version: N/A Type: F-port State: online Supported Speeds: not established Current Speed: 2Gb Node WWN: 200100e08bb09221 HBA Port WWN: 210000e08b909221 Port Mode: Target Port ID: 10900 OS Device Name: Not Applicable Manufacturer: QLogic Corp. Model: d37ad1e0 Firmware Version: 4.0.109 FCode/BIOS Version: N/A Type: F-port State: online Supported Speeds: not established Current Speed: 2Gb Node WWN: 200000e08b909221
Example 3 Listing HBA Ports and Link Statistics
The following command lists information for the HBA ports and the link statistics for those ports:
# fcinfo hba-port -l 210000e08b074cb5 210100e08b274cb5 HBA Port WWN: 210000e08b074cb5 Port Mode: Initiator OS Device Name: /dev/cfg/c1 Manufacturer: QLogic Corp. Model: 375-3108-xx Firmware Version: 3.3.116 FCode/BIOS Version: 1.13.08 Serial Number: 0402F00-0549112808 Driver Name: qlc Driver Version: 20070212-2.19 Type: N-port State: online Supported Speeds: 1Gb 2Gb Current Speed: 2Gb Node WWN: 200000e08b074cb5 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 0 Loss of Signal Count: 0 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 HBA Port WWN: 210100e08b274cb5 Port Mode: Initiator OS Device Name: /dev/cfg/c2 Manufacturer: QLogic Corp. Model: 375-3108-xx Firmware Version: 3.3.116 FCode/BIOS Version: 1.13.08 Serial Number: 0402F00-0549112808 Driver Name: qlc Driver Version: 20070212-2.19 Type: N-port State: online Supported Speeds: 1Gb 2Gb Current Speed: 2Gb Node WWN: 200100e08b274cb5 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 0 Loss of Signal Count: 0 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0
Example 4 Listing All Remote Ports
The following command lists all remote ports that are visible through the given HBA port:
# fcinfo remote-port -p 210100e08b274cb5 Remote Port WWN: 50020f230000b4af Active FC4 Types: SCSI SCSI Target: yes Port Symbolic Name: unknown Node WWN: 50020f200000b4af Remote Port WWN: 210000e08b07daa6 Active FC4 Types: SCSI SCSI Target: no Port Symbolic Name: unknown Node WWN: 200000e08b07daa6 Remote Port WWN: 20030003ba27c788 Active FC4 Types: SCSI SCSI Target: yes Port Symbolic Name: unknown Node WWN: 10000003ba27c788 Remote Port WWN: 210000e08b096a60 Active FC4 Types: SCSI,IP SCSI Target: no Port Symbolic Name: unknown Node WWN: 200000e08b096a60
Example 5 Listing Remote Ports and Link Statistics
The following command lists information for the remote ports and the link statistics for those ports:
# fcinfo remote-port -l -p 210100e08b272ab5 Remote Port WWN: 210100e08b296a60 Active FC4 Types: SCSI,IP SCSI Target: no Port Symbolic Name: unknown Node WWN: 200100e08b296a60 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 0 Loss of Signal Count: 0 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 Remote Port WWN: 20030003ba27d56d Active FC4 Types: SCSI SCSI Target: yes Port Symbolic Name: unknown Node WWN: 10000003ba27d56d Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 4765165 Loss of Signal Count: 4765165 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 Remote Port WWN: 210100e08b27f7a6 Active FC4 Types: SCSI SCSI Target: no Port Symbolic Name: unknown Node WWN: 200100e08b27f7a6 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 0 Loss of Signal Count: 0 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 Remote Port WWN: 50020f230000b897 Active FC4 Types: SCSI SCSI Target: yes Port Symbolic Name: unknown Node WWN: 50020f200000b897 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 7 Loss of Signal Count: 7 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 Remote Port WWN: 210100e08b27daa6 Active FC4 Types: SCSI SCSI Target: no Port Symbolic Name: unknown Node WWN: 200100e08b27daa6 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 0 Loss of Signal Count: 0 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 Remote Port WWN: 210000e08b074cb5 Active FC4 Types: SCSI,IP SCSI Target: no Port Symbolic Name: unknown Node WWN: 200000e08b074cb5 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 0 Loss of Signal Count: 0 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 Remote Port WWN: 210100e08b296060 Active FC4 Types: SCSI SCSI Target: no Port Symbolic Name: unknown Node WWN: 200100e08b296060 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 0 Loss of Signal Count: 0 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0
Example 6 Listing All SCSI Targets and Link Statistics
The following command lists all remote ports as well as the link statistics and scsi-target information:
# fcinfo remote-port -sl -p 210100e08b272ab5 Remote Port WWN: 210100e08b296a60 Active FC4 Types: SCSI,IP SCSI Target: no Port Symbolic Name: unknown Node WWN: 200100e08b296a60 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 0 Loss of Signal Count: 0 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 Remote Port WWN: 20030003ba27d56d Active FC4 Types: SCSI SCSI Target: yes Port Symbolic Name: unknown Node WWN: 10000003ba27d56d Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 4765165 Loss of Signal Count: 4765165 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 LUN: 0 Vendor: SUN Product: T4 OS Device Name: /dev/rdsk/c4t20030003BA27D56Dd0s2 LUN: 1 Vendor: SUN Product: T4 OS Device Name: /dev/rdsk/c4t20030003BA27D56Dd1s2 Remote Port WWN: 210100e08b27f7a6 Active FC4 Types: SCSI SCSI Target: no Port Symbolic Name: unknown Node WWN: 200100e08b27f7a6 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 0 Loss of Signal Count: 0 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 Remote Port WWN: 50020f230000b897 Active FC4 Types: SCSI SCSI Target: yes Port Symbolic Name: unknown Node WWN: 50020f200000b897 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 7 Loss of Signal Count: 7 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 LUN: 0 Vendor: SUN Product: T300 OS Device Name: Unknown LUN: 1 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d1s2 LUN: 2 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d2s2 LUN: 3 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d3s2 LUN: 4 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d4s2 LUN: 5 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d5s2 LUN: 6 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d6s2 LUN: 7 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d7s2 LUN: 8 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d8s2 LUN: 9 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d9s2 LUN: 10 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d10s2 LUN: 11 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d11s2 LUN: 12 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d12s2 LUN: 13 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d13s2 LUN: 14 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d14s2 LUN: 15 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d15s2 Remote Port WWN: 210100e08b27daa6 Active FC4 Types: SCSI SCSI Target: no Port Symbolic Name: unknown Node WWN: 200100e08b27daa6 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 0 Loss of Signal Count: 0 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 Remote Port WWN: 210000e08b074cb5 Active FC4 Types: SCSI,IP SCSI Target: no Port Symbolic Name: unknown Node WWN: 200000e08b074cb5 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 0 Loss of Signal Count: 0 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 Remote Port WWN: 210100e08b296060 Active FC4 Types: SCSI SCSI Target: no Port Symbolic Name: unknown Node WWN: 200100e08b296060 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 0 Loss of Signal Count: 0 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0
Example 7 Listing SCSI Target Information
The following command lists all remote ports as well as the scsi-target information:
# fcinfo remote-port -s -p 210100e08b272ab5 Remote Port WWN: 210100e08b296a60 Active FC4 Types: SCSI,IP SCSI Target: no Port Symbolic Name: unknown Node WWN: 200100e08b296060 Remote Port WWN: 20030003ba27d56d Active FC4 Types: SCSI SCSI Target: yes Port Symbolic Name: unknown Node WWN: 10000003ba27d56d LUN: 0 Vendor: SUN Product: T4 OS Device Name: /dev/rdsk/c4t20030003BA27D56Dd0s2 LUN: 1 Vendor: SUN Product: T4 OS Device Name: /dev/rdsk/c4t20030003BA27D56Dd1s2 Remote Port WWN: 210100e08b27f7a6 Active FC4 Types: SCSI SCSI Target: no Port Symbolic Name: unknown Node WWN: 200100e08b27f7a6 Remote Port WWN: 50020f230000b897 Active FC4 Types: SCSI SCSI Target: yes Port Symbolic Name: unknown Node WWN: 50020f200000b897 LUN: 0 Vendor: SUN Product: T300 OS Device Name: Unknown LUN: 1 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d1s2 LUN: 2 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d2s2 LUN: 3 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d3s2 LUN: 4 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d4s2 LUN: 5 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d5s2 LUN: 6 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d6s2 LUN: 7 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d7s2 LUN: 8 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d8s2 LUN: 9 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d9s2 LUN: 10 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d10s2 LUN: 11 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d11s2 LUN: 12 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d12s2 LUN: 13 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d13s2 LUN: 14 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d14s2 LUN: 15 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d15s2 Remote Port WWN: 210100e08b27daa6 Active FC4 Types: SCSI SCSI Target: no Port Symbolic Name: unknown Node WWN: 200100e08b27daa6 Remote Port WWN: 210000e08b074cb5 Active FC4 Types: SCSI,IP SCSI Target: no Port Symbolic Name: unknown Node WWN: 200000e08b074cb5 Remote Port WWN: 210100e08b296060 Active FC4 Types: SCSI SCSI Target: no Port Symbolic Name: unknown Node WWN: 200100e08b296060
Example 8 Listing the Logical Unit
The following command lists the logical unit:
# fcinfo logical-unit /dev/rdsk/c0t600C0FF0000000000036223AE73EB705d0s2 /dev/rdsk/c0t600C0FF00000000000362272539E5B03d0s2 /dev/rmt/0n
Example 9 Displaying Additional Information for the Logical Unit
The following command displays additional information about the logical unit using the -v option for device /dev/rmt/On:
# fcinfo lu -v /dev/rmt/On OS Device Name: /dev/rmt/0n HBA Port WWN: 210000e07c030b91 Remote Port WWN: 21010003b7830a6 LUN: 0 Vendor: STK Product: 9940A Device Type: Tape device
The following command displays additional information about the logical unit using the -v option for device /dev/rdsk/c0t600C0FF0000000000036223AE73EB705d0s2
# fcinfo logical-unit -v \ /dev/rdsk/c0t600C0FF0000000000036223AE73EB705d0s2 OS Device Name: /dev/rdsk/c0t600C0FF0000000000036223AE73EB705d0s2 HBA Port WWN: 210100e08b27a8a1 Remote Port WWN: 256000c0ffc03622 LUN: 0 Remote Port WWN: 216000c0ff803622 LUN: 0 HBA Port WWN: 210000e08b07a8a1 Remote Port WWN: 256000c0ffc03622 LUN: 0 Remote Port WWN: 216000c0ff803622 LUN: 0 Vendor: SUN Product: StorEdge 3510 Device Type: Disk device
Example 10 Adding an NIPV Port
The following command adds an NPIV port to the HBA with a port name:
210000e08b170f1c
The NPIV port has a port name of 2000000000000001 and a node name of 2100000000000001.
# fcadm create-npiv-port -p 2000000000000001 -n 2100000000000001 \ 210000e08b170f1c Created NPIV Port: HBA Port WWN: 2000000000000001 Node WWN: 2100000000000001 Physical HBA Port WWN: 210000e08b170f1c
Example 11 Adding an NIPV Port with Random WWN
The following command adds an NPIV port to the HBA with a randomly assigned port name of 210000e08b170f1c.
# fcadm create-npiv-port 210000e08b170f1c Created NPIV Port: HBA Port WWN: 2038295824942801 Node WWN: 2100392849248001 Physical HBA Port WWN: 210000e08b170f1c
Example 12 Deleting an NIPV Port
The following command deletes an NPIV port.
# fcadm delete-npiv-port -p 2000000000000001 -w 2100000000000001 \ 210000e08b170f1c
See attributes(5) for descriptions of the following attributes:
|
attributes(5)
Errors that can occur in addition to the errors normally associated with system administration commands: