The OpenNET Project / Index page

[ новости /+++ | форум | теги | ]

Интерактивная система просмотра системных руководств (man-ов)

 ТемаНаборКатегория 
 
 [Cписок руководств | Печать]

metasync (1)
  • >> metasync (1) ( Solaris man: Команды и прикладные программы пользовательского уровня )
  •  

    NAME

    metasync - handle metadevice resync during reboot
     
    

    SYNOPSIS

    /usr/sbin/metasync -h
    

    /usr/sbin/metasync [-s setname] [buffer_size] metadevice
    

    /usr/sbin/metasync [-s setname] -r [buffer_size]
    

    /usr/sbin/metasync -p metadevice
    

    /usr/sbin/metasync -c metadevice
    

     

    DESCRIPTION

    The metasync command starts a resync operation on the specified metadevice. All components that need to be resynced are resynced. If the system crashes during a RAID5 initialization, or during a RAID5 resync, either an initialization or resync restarts when the system reboots.

    Applications are free to access a metadevice at the same time that it is being resynced by metasync. Also, metasync performs the copy operations from inside the kernel, which makes the utility more efficient.

    Use the -r option in boot scripts to resync all possible submirrors.  

    OPTIONS

    The following options are supported:

    -c metadevice

    Cancels the resync that is in progress on the specified metadevice. The resync will be stopped at its current point and can be resumed by running the "metasync metadevice" command. This option only applies to RAID1 volumes.

    -h

    Displays usage message.

    -p metadevice

    Regenerates parity information for RAID5 metadevices.

    -s setname

    Specifies the name of the diskset on which metasync will work. Using the -s option will cause the command to perform its administrative function within the specified diskset. Without this option, the command will perform its function on local metadevices.

    -r

    Specifies that the metasync command handle special resync requirements during a system reboot. metasync -r should only be invoked from the svc:/system/mdmonitor service. The metasync command only resyncs those metadevices that need to be resynced. metasync schedules all the mirror resyncs according to their pass numbers.

    To override the default buffer_size value used by the svc:/system/mdmonitor service, you can edit /etc/system to specify:

    set md_mirror:md_resync_bufsz = 2048
    

    so that resyncs occur as quickly as possible.

     

    OPERANDS

    buffer_size

    Specifies the size (number of 512-byte disk blocks) of the internal copy buffer for the mirror resync. The size defaults to 1024 512-byte disk blocks. It can be no more than 2048 blocks. For best performance (quickest completion of the resync), 2048 blocks is the recommended size.

     

    EXIT STATUS

    The following exit values are returned:

    0

    Successful completion.

    >0

    An error occurred.

     

    ATTRIBUTES

    See attributes(5) for descriptions of the following attributes:

    ATTRIBUTE TYPEATTRIBUTE VALUE

    AvailabilitySUNWmdu

     

    SEE ALSO

    mdmonitord(1M), metaclear(1M), metadb(1M), metadetach(1M), metahs(1M), metainit(1M), metaoffline(1M), metaonline(1M), metaparam(1M), metarecover(1M), metarename(1M), metareplace(1M), metaroot(1M), metaset(1M), metassist(1M), metastat(1M), metattach(1M), md.tab(4), md.cf(4), mddb.cf(4), md.tab(4), attributes(5), md(7D)

     

    NOTES

    The metasync service is managed by the service management facility, smf(5), under the service identifier:

    svc:/system/mdmonitor
    

    Administrative actions on this service, such as enabling, disabling, or requesting restart, can be performed using svcadm(1M). The service's status can be queried using the svcs(1) command.


     

    Index

    NAME
    SYNOPSIS
    DESCRIPTION
    OPTIONS
    OPERANDS
    EXIT STATUS
    ATTRIBUTES
    SEE ALSO
    NOTES


    Поиск по тексту MAN-ов: 




    Партнёры:
    PostgresPro
    Inferno Solutions
    Hosting by Hoster.ru
    Хостинг:

    Закладки на сайте
    Проследить за страницей
    Created 1996-2024 by Maxim Chirkov
    Добавить, Поддержать, Вебмастеру