    NAME
         sdtperfmeter - the CDE Performance Meter
    
    SYNOPSIS
         sdtperfmeter [ -a ] [ -s sample-time ] [ -l ] [  -n  sample-
         filename  ] [ -p page-length ] [ -t meter ] [ -C meter ceil-
         ing ] [ -H ] [ -L ] [ -S ] [ -V ] [ -Wn ] [ +Wn ] [ -?  ]  [
         hostname ]
    
    DESCRIPTION
         The sdtperfmeter client displays performance statistics  for
         a  given  hostname.   If no host is specified, statistics on
         the current host are metered.  You can  display  performance
         values in a solid or line strip chart.  The performance data
         automatically scales to accommodate increasing or decreasing
         values  for  the  host  machine.   The sdtperfmeter property
         sheet provides a simple interface for accessing all  of  the
         application resources.
    
    OPTIONS
         -a   Display all the performance  statistics  meters  simul-
              taneously.
    
         -s sample-time
              Set the sample time interval in seconds.
    
         -l   Turn statistic logging on.
    
         -n sample-filename
              Specifies the filename to log the  statistics  to.   If
              the file exists, the data is appended.
    
         -p page-length
              Sets the page length for perfmeter samples  written  to
              file. The default is 60 lines per page.
    
         -t meter
              Specifies a meter  to  display.   This  option  can  be
              present multiple times.
    
              meter
                   The following meters are currently available:
    
              cpu     Percent of CPU being usage.
    
              pkts    Ethernet packets per second.
    
              page    Paging activity in pages per second.
    
              swap    Jobs swapped per second.
    
              intr    Number of device interrupts per second.
              disk    Disk traffic in transfers per second.
    
              cntxt   Number of context switches per second.
    
              load    Average number of runnable processes  over  the
                      last minute.
    
              colls   Collisions per second detected on the ethernet.
    
              errs    Errors per second on receiving packets.
    
         -v   Show version number
    
         -C meter ceiling
              Set a ceiling value for a given meter.  Any data  value
              above this ceiling will drawn in the limit color.
    
         -H   Display meters in a horizontal orientation.
    
         -L   Display the meters as line strip charts.
    
         -S   Display the meters as solid line strip charts.
    
         -V   Display meters in a vertical orientation.
    
         -Wn  Hide the Window Manager Title decoration.
    
         +Wn  Show the Window Manager Title decoration.
    
         -?   Print the program usage on stderr.
    
         hostname
              The hostname of the machine to monitor.
    
    
    RESOURCES
         The sdtperfmeter application  allows  the  user  to  specify
         behavior  through X11 resources, the command line interface,
         and property sheets. The X11 resources can be added to  your
         Sdtperfmeter  located  in your XAPPLRESDIR.  There are three
         kinds of resources types: general,  host,  and  meter.   The
         following  definitions  contain  examples  of  how to define
         these resources.
    
         The  general  resources  include  all  of  the  standard   X
         resources  plus a few application specific ones and apply to
         the entire application.  To set any general resource, define
         it as follows:
    
              Sdtperfmeter*name: value
    
    
         The host resources apply to a specific host machine  To  set
         any host resource, define it as follows:
    
              Sdtperfmeter.host*name: value
    
         The meter resources apply to a specific meter.  To  set  any
         meter resource, define it as follows:
    
              Sdtperfmeter*meter.name: value
    
         or as a host specific meter resource:
    
              Sdtperfmeter.host.meter.name: value
    
         Following is a  list  of  the  defined  resources:   center,
         expand;   cf3      cf3      cf3      cf3  lf3w(2c)  lf3w(2c)
         lf3w(1c) lf3w(2c)  .   Name     Class    Type     Default  _
         autoLoadByHost AutoLoadByHost Boolean   False
         background     Background     String    white
         canvasColor    CanvasColor    int  0
         collectWhenIconized CollectWhenIconized Boolean   False
         curMax    CurMax    int
         displayList    DisplayList    StringTable    cpu
         foreground     Foreground     String    black
         graphType GraphType String    line
         loadByHost     LoadByHost     Boolean   True
         labelColor     LabelColor     int  1
         labelFont LabelFont XmFontList     fixed
         limit     Limit     int
         limitColor     LimitColor     int  1
         log  Log  Boolean   True
         logFilename    LogFilename    String
         logPageLength  LogPageLength  int  60
         machineNames   MachineNames   StringTable
         maxMax    MaxMax    int
         meterColor     MeterColor     int  1
         minMax    MinMax    int
         direction Direction String    vertical
         saveByHost     SaveByHost     Boolean   True
         saveAsFile     SaveAsHost     Boolean   False
         sampleTime     SampleTime     int  2
         sizeToFit SizeToFit Boolean   True
         showLimit ShowLimit Boolean   False
         showMenubar    ShowMenubar    Boolean   False
         showStatus     ShowStatus     Boolean   False
         showTitle ShowTitle Boolean   False
         wrapCount WrapCount int  10
    
         autoLoadByHost
              Automatically load host specific resource when the mon-
              itor host is changed.
    
         background
              The background color of the application
    
         canvasColor
              This resource specifies the Canvas Color.  This  is  an
              index into the application color palette.
    
         collectWhenIconized
              If True, the application will continue to  sample  when
              iconized.
    
         curMax
              Set the current sampling limit.
    
         displayList
              Specifies the list of meters to display.  The supported
              values  are:  cpu,  pkts, page, swap, intr, disk, cntx,
              load, coll, errs
    
         foreground
              The foreground color of the application
    
         graphType
              Specifies the type of meter to display.  The  supported
              values are: line, solid.
    
         loadByHost
              If True, load the resources by hostname.
    
         labelColor
              Sets the meter label color. This is an index  into  the
              application color palette.
    
         labelFont
              Set the meter label FontList.
    
         limit
              Set the limit data value.  Any sample data  above  this
              limit will be drawn in the limitColor
    
         limitColor
              Sets the meter limit color. This is an index  into  the
              application color palette.
    
         log  If True, turn on logging to the file specified in  log-
              Filename.
    
         logFilename
              Specifies the file to log statistics to.
    
         logPageLength
              Sets the log output page length.
    
         machineNames
              Specifies a list of commonly monitored hostnames.  This
              list is displayed in the property sheet.
    
         maxMax
              Set the upper data sampling limit.
    
         meterColor
              Sets the upper data sampling limit.  This is  an  index
              into the application color palette.
    
         minMax
              Set the lower data sampling limit.
    
         orientation
              Set the orientation of the  visible  meters.  The  sup-
              ported values are: horizontal, vertical.
    
         saveByHost
              If True, save the resources by hostname.
    
         saveAsFile
              If True, prompt the user for a  filename  to  save  the
              resource too.
    
         sampleTime
              This specifies the monitor sample time interval.
    
         resizeable
              If True, this allows the canvas area to grow and shrink
              as  needed  depending  on  number  and  type of visible
              meters.
    
         showLimit
              Display the limit line fi  the  graphType  is  line  or
              solid.
    
         showMenubar
              Display the Menubar and the pulldown menus.
    
         showStatus
              Display the status line which contains the name of  the
              remote host.
    
         showTitle
              Show the Window Manager Title decorations.
    
         wrapCount
              Set the meter wrap count in the current orientation.
    
    
    
    TRANSLATIONS
         The sdtperfmeter application defines a set of  translations,
         which map keyboard events into actions, on the meter canvas.
         These translations allow quick access to commonly used  com-
         mands  and  can  be  reconfigured.  The default meter canvas
         translations are:
    
         <Key>a: PmShow(all)
         <Key>c: PmShow(cpu)
         <Key>d: PmShow(disk)
         <Key>e: PmShow(errs)
         <Key>g: PmShow(page)
         <Key>i: PmShow(intr)
         <Key>k: PmShow(pkts)
         <Key>l: PmShow(load)
         <Key>m: PmToggle(menubar)
         <Key>m: PmToggle(monitor)
         <Key>o: PmShow(coll)
         <Key>p: PmShow(props)
         <Key>q: PmQuit()
         <Key>s: PmToggle(graphstyle)
         <Key>t: PmToggle(showlimitline)
         <Key>w: PmShow(swap)
         <Key>x: PmShow(cntx)
         <Key>y: PmToggle(orientation)
         <Key>1: PmInterval(sample, 1)
         <Key>2: PmInterval(sample, 2)
         <Key>3: PmInterval(sample, 3)
         <Key>4: PmInterval(sample, 4)
         <Key>5: PmInterval(sample, 5)
         <Key>6: PmInterval(sample, 6)
         <Key>7: PmInterval(sample, 7)
         <Key>8: PmInterval(sample, 8)
         <Key>9: PmInterval(sample, 9)
    
         To override the  default  translations,  add  the  following
         resource  to  your  .Xdefaults  or  Sdtperfmeter application
         resource file:
              Sdtperfmeter*Canvas.translations:   #override   <Key>a:
              PmShow(all)0..
    
    
    ACTIONS
         The sdtperfmeter application defines  the  following  action
         procedures:
    
         PmShow(meter)
              Show the specified meter.  The supported  meter  values
              are:  all,  cpu,  pkts,  page,  swap, intr, disk, cntx,
              load, coll, errs.
    
         PmToggle(resource)
              Toggle  various  resources.   The  supported   resource
              values  are:   orientation,  graphstyle,  log, monitor,
              menubar, title.
    
         PmInterval(interval,value)
              Set the interval to the specified value.  The supported
              intervals are: sample.
    
         PmQuit()
              Quit the application.
    
    EXIT STATUS
         0    successful completion
    
         >0   an error occurred
    
    FILES
         $HOME/.dt/Desktop/$HOME.resources
              User resource file.
    
         $HOME/sdtperfmeterlog$PID
              Default logfile name, where $PID is substituted by get-
              pid().
    
    SEE ALSO
         netstat(1M), rpc.rstatd(1M), vmstat(1M),
    
    NOTES
         The rpc.rstatd (1M) daemon must be running  on  the  machine
         being metered.
    
    
    
    