isdnd.rates - isdn4bsd ISDN management daemon rates description file
The format of a rate entry line is as follows:
The first field, the (Fa rate-code ) defines a collection of rates (for each day of the week) which can be referenced in the isdnd(8) configuration file isdnd.rc5. This field must start with the identifier ``ra'' followed by a digit in the range of zero to four.
The second field, the (Fa day-number ) selects the day of week for which this entry defines the rates, where 0 stands for Sunday, 1 for Monday and so on until the digit 6 which stands for Saturday.
The rest of the line consists of one or more space separated fields which have the following syntax:
start_hour.start_minutes-end_hour.end_minutes:charge_unit_length
Start_hour and start_minutes define the begin of a time section and end_hour and end_minutes define the end. Charge_unit_length define the length of a charging unit in the previously defined time section. No spaces or tabs are allowed inside this field. The hour and minutes specifications MUST have exactly 2 digits, in case just one digit is needed, a leading 0 must be used.
For example,
14.00-18.00:90
defines, that between 2:00 PM and 6:00 PM the length of one charging unit lasts 90 seconds.
ra0 0 00.00-05.00:240 05.00-21.00:150 21.00-24.00:240
defines the unit lengths for a Sunday.
The isdnd(8) daemon and this manual page were written by An Hellmuth Michaelis Aq [email protected] .
Закладки на сайте Проследить за страницей |
Created 1996-2024 by Maxim Chirkov Добавить, Поддержать, Вебмастеру |