sane-microtek - SANE backend for Microtek scanners
Transparent Media Adapter
Document AutoFeeder
The driver supports line art, halftone, 8bpp gray, and 24bpp color scans at normal and "expanded" resolutions (i.e. 1200x1200 on an E6), fast scans for color previews, and downloadable gamma tables.
The supported scanners are all SCSI scanners. However, some parallel port models may work (under Linux), if they use a parport->scsi chip, and if you can find a scsi->parport driver. This is known to be the case for the Color PageWiz.
The driver does not support the newest Microtek scanners, such as the V330 and V660, which use a new and very different SCSI-II command set. For those, try the alternate microtek2 backend. Most non-SCSI scanners would use the new command set. Most scanners newer than the Scanmaker E6 would use the new command set.
If you own a Microtek scanner other than the ones listed above, tell us what happens --- see the BUGS section at the end of this document.
Although this manual page is generally updated with each release,
up-to-date information on new releases and extraneous helpful hints
are available from the backend homepage:
Where special is the UNIX path-name for the special device that corresponds to the scanner. The special device name must be a generic SCSI device or a symlink to such a device. Under Linux, such a device name could be /dev/sga or /dev/sge, for example.
The configuration file may also contain the special tokens norealcal or noprecal. norealcal will disable the use of magic, undocumented scanner calibration commands which are known to work on the E6, but may not work with other models. noprecal will disable logic which tries to avoid scanner precalibration. This logic would only have been activated if the magic calibration code was turned off.
i.e. don't complain about these --- but if brightness and/or contrast do work for you, please tell me.
If your scanner locks up, try setting the norealcal or noprecal option in the configuration file (first one, then both), and see if it helps. (If it does, report it.)
Send lengthy bug reports and new scanner information to [email protected]. All bug reports and new scanner inquiries should include an error log file. You can generate copious stderr output by setting the SANE_DEBUG_MICROTEK environment variable described above. For example:
More general comments, suggestions, and inquiries about frontends or SANE should go to [email protected], the SANE Developers mailing list. Have a look at http://www.sane-project.org/mailing-lists.html concerning subscription to sane-devel.
Закладки на сайте Проследить за страницей |
Created 1996-2024 by Maxim Chirkov Добавить, Поддержать, Вебмастеру |