    NAME

    
    
    atacontrol
    
     - ATA device driver control program
    
     
    

    SYNOPSIS

    Aq Ar command args


    attach channel
    detach channel
    reinit channel
    create type [interleave disk0 ... diskN ]
    delete raid
    addspare raid disk
    rebuild raid
    status raid
    mode device
    info channel
    cap device
    spindown device [seconds ]
    list  

    DESCRIPTION

    The utility is a control program that provides the user access and control to the Fx ata(4) subsystem.

    The utility can cause severe system crashes and loss of data if used improperly. Please exercise caution when using this command!

    The channel argument is the ATA channel device (e.g., ata0) on which to operate. The following commands are supported:

    attach
    Attach an ATA channel Devices on the channel are probed and attached as is done on boot.
    detach
    Detach an ATA channel Devices on the channel are removed from the kernel, and all outstanding transfers etc. are returned back to the system marked as failed.
    reinit
    Reinitialize an ATA channel Both devices on the channel are reset and initialized to the parameters the ATA driver has stored internally. Devices that have gone bad and no longer respond to the probe, or devices that have physically been removed, are removed from the kernel. Likewise are devices that show up during a reset, probed and attached.
    create
    Create a type ATA RAID. The type can be RAID0 (stripe), RAID1 (mirror), RAID0+1 SPAN or JBOD In case the RAID has a RAID0 component, the interleave must be specified in number of sectors. The RAID will be created of the individual disks named -words disk0 ... diskN

    Although the ATA driver allows for creating an ATA RAID on disks with any controller, there are restrictions. It is only possible to boot on an array if it is either located on a ``real'' ATA RAID controller like the Promise or Highpoint controllers, or if the RAID declared is of RAID1 or SPAN type; in case of a SPAN the partition to boot must reside on the first disk in the SPAN.

    delete
    Delete a RAID array on a RAID capable ATA controller.
    addspare
    Add a spare disk to an existing RAID.
    rebuild
    Rebuild a RAID1 array on a RAID capable ATA controller.
    status
    Get the status of an ATA RAID.
    mode
    Without the mode argument, the current transfer modes of the device are printed. If the mode argument is given, the ATA driver is asked to change the transfer mode to the one given. The ATA driver will reject modes that are not supported by the hardware. Modes are given like ``PIO3 '' ``udma2 '' ``udma100 '' case does not matter.

    Currently supported modes are: PIO0 , PIO1 , PIO2 , PIO3 , PIO4 WDMA2 UDMA2 (alias UDMA33 ) UDMA4 (alias UDMA66 ) UDMA5 (alias UDMA100 and UDMA6 (alias UDMA133 ) The device name and manufacture/version strings are shown.

    cap
    Show detailed info about the device on device
    spindown
    Set or report timeout after which the device will be spun down. To arm the timeout the device needs at least one more request after setting the timeout. To disable spindown, set the timeout to zero. No further actions are needed in this case.
    info
    Show info about the attached devices on the channel
    list
    Show info about all attached devices on all active controllers.

     

    EXAMPLES

    To get information on devices attached to a channel, use the command line:

    "atacontrol info ata0"

    To see the devices' current access modes, use the command line:

    "atacontrol mode ad0"

    which results in the modes of the devices being displayed as a string like this:

    "current mode = UDMA100"

    You can set the mode with and a string like the above, for example:

    "atacontrol mode ad0 PIO4"

    The new modes are set as soon as the command returns.

    The atacontrol command can also be used to create purely software RAID arrays in systems that do NOT have a "real" hardware RAID card such as a Highpoint or Promise card. A common scenario is a 1U server such as the HP DL320 G4 or G5. These servers contain a SATA controller that has 2 channels that can contain 2 disks per channel, but the servers are wired to only place a single SATA drive on each channel. These servers do have a "pseudo" RAID BIOS but it uses a proprietary format that is not compatible with the ata driver, and thus their RAID bios must be switched off. Another common scenario would be a Promise UDMA100 controller card that did not contain the Fasttrack RAID BIOS, but did contain 2 UDMA channels. 1 disk would be attached to one channel and the other disk would be attached to the other channel. It is NOT recommended to create such arrays on a primary/secondary pair on a SINGLE channel since the throughput of the mirror would be severely compromised, the ability to rebuild the array in the event of a disk failure would be greatly complicated, and if a disk controller electronics failed it could wedge the channel and take both disks in the mirror offline. (which would defeat the purpose of having a mirror in the first place)

    A quick and dirty way to create such a mirrored array on a new system is to boot off the FreeBSD install CD, do a minimal scratch install, abort out of the post install questions, and at the command line issue the command:

    "atacontrol create RAID1 ad4 ad6"

    then immediately issue a reboot and boot from the installation CD again, and during the installation, you will now see "ar0" listed as a disk to install on, and install on that instead of ad4, ad6, etc.

    To get information about the status of a RAID array in the system use the command line:

    "atacontrol status ar0"

    A typical output showing good health on a RAID array might be as follows:

    "ar0: ATA RAID1 subdisks: ad4 ad6 status: READY"

    If a disk drive in a RAID1 array dies the system will mark the disk in a DOWN state and change the array status to DEGRADED. This can ALSO happen in rare instances due to a power fluctuation or other event causing the system to not shutdown properly. In that case the output will look like the following:

    "ar0: ATA RAID1 subdisks: ad4 DOWN status: DEGRADED"

    For a mirrored RAID1 system the server WILL ALLOW you to remove a dead SATA disk drive (if the drive is in a hot-swap tray) without freezing up the system, so you can remove the disk and while you are obtaining a replacement the server can run from the active disk. The only caveat is that if the active disk is ad6, the system most likely will NOT be able to be rebooted since most systems only support booting from the first disk drive.

    To deactivate the DOWN disk ad6 to allow for it to be ejected, use the following:

    "atacontrol detach ata3"

    then eject or remove the disk. Note that this only works if the 2 disks in the mirror are on separate channels (which is the standard setup for 1-U servers like the HP DL320). When the new disk drive is obtained, make sure it is blank, then shut the system down. At this point, if the system has a RAID array card like a Highpoint or Promise controller, you may then boot it into the BIOS of the card and use the manufacturers RAID array rebuild utilities to rebuild the array.

    If the system has a pure software array and is not using a "real" ATA RAID controller, then shut the system down, make sure that the disk that was still working is moved to the bootable position (channel 0 or whatever the BIOS allows the system to boot from) and the blank disk is placed in the secondary position, then boot the system into single-user mode and issue the command:

    "atacontrol addspare ar0 ad6"
    "atacontrol rebuild ar0"

    If the disk drive did NOT fail and the RAID array became unmirrored due to a software glitch or improper shutdown, then a slightly different process must be followed. Begin by issuing the detach command (this shows the detach for disk ad6, the primary master on channel 3):

    "atacontrol detach ata3"

    then reboot the system into single-user mode. (don't just init the system, reboot it so that both disks get probed) You will probably see TWO mirrored RAID arrays appear during the boot messages, ar0 and ar1. Issue the command:

    "atacontrol delete ar1"
    "atacontrol addspare ar0 ad6"

    Now a status command will show the array rebuilding.

    To spin down a disk after 30 minutes run

    "atacontrol spindown ad6 1800"
    "dd if=/dev/ad6 of=/dev/null count=1"

    While any IO on the disk will arm the timer, using dd(1) on the raw device will work in all cases, as when the disk is not opened at all. You can check the current setting with

    "atacontrol spindown ad6"

    You should not set a spindown timeout on a disk with / or syslog logging on it as the disk will be worn out spinning down and up all the time.  

    SEE ALSO

    ata(4)  

    HISTORY

    The utility first appeared in Fx 4.6 .  

    AUTHORS

    An -nosplit The utility was written by An S/oren Schmidt Aq [email protected] .

    This manual page was written by An S/oren Schmidt Aq [email protected] .


     

    Index

    NAME
    SYNOPSIS
    DESCRIPTION
    EXAMPLES
    SEE ALSO
    HISTORY
    AUTHORS